TX® (I) 331 - 150/250 (300) V
TX® (I) 331 - 150/250 (300) V
INSTRUMENTATION, CONTROL AND COMMUNICATION CABLES
Read moreTX® ( I ) 331 150/250V 1P0.75
Nexans ref. 25405350
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 6.6 mm
- Maximum outer diameter: 8.2 mm
- 무게(근사치): 80 kg/km
TX® ( I ) 331 150/250V 2P0.75
Nexans ref. 10171346
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 10.0 mm
- Maximum outer diameter: 12.5 mm
- 무게(근사치): 150 kg/km
TX® ( I ) 331 150/250V 4P0.75
Nexans ref. 10282801
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 14.5 mm
- 무게(근사치): 210 kg/km
TX® ( I ) 331 150/250V 7P0.75
Nexans ref. 10171349
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 17.5 mm
- 무게(근사치): 340 kg/km
TX® ( I ) 331 150/250V 10P0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 17.0 mm
- Maximum outer diameter: 21.0 mm
- 무게(근사치): 470 kg/km
TX® ( I ) 331 150/250V 14P0.75
Nexans ref. 10171351
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 23.5 mm
- 무게(근사치): 630 kg/km
TX® ( I ) 331 150/250V 19P0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 22.5 mm
- Maximum outer diameter: 27.0 mm
- 무게(근사치): 830 kg/km
TX® ( I ) 331 150/250V 24P0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 24
- Number of triples: -
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 25.0 mm
- Maximum outer diameter: 30.0 mm
- 무게(근사치): 1060 kg/km
TX® ( I ) 331 150/250V 1T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 1
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 7.0 mm
- Maximum outer diameter: 8.6 mm
- 무게(근사치): 80 kg/km
TX® ( I ) 331 150/250V 2T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 14.5 mm
- 무게(근사치): 210 kg/km
TX® ( I ) 331 150/250V 4T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 13.0 mm
- Maximum outer diameter: 16.0 mm
- 무게(근사치): 270 kg/km
TX® ( I ) 331 150/250V 7T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 7
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 16.5 mm
- Maximum outer diameter: 20.5 mm
- 무게(근사치): 450 kg/km
TX® ( I ) 331 150/250V 10T0.75
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 10
- 도체 단면적: 0.75 mm²
- Minimum outer diameter: 19.5 mm
- Maximum outer diameter: 23.5 mm
- 무게(근사치): 660 kg/km
TX® ( I ) 331 150/250V 1P1.5
Nexans ref. 10171354
- Packaging: Cut to length (m)
- Number of pairs: 1
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 7.8 mm
- Maximum outer diameter: 9.2 mm
- 무게(근사치): 100 kg/km
TX® ( I ) 331 150/250V 2P1.5
Nexans ref. 10171356
- Packaging: Cut to length (m)
- Number of pairs: 2
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 12.0 mm
- Maximum outer diameter: 14.0 mm
- 무게(근사치): 220 kg/km
TX® ( I ) 331 150/250V 4P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 4
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 16.5 mm
- 무게(근사치): 310 kg/km
TX® ( I ) 331 150/250V 7P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 7
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 17.5 mm
- Maximum outer diameter: 20.0 mm
- 무게(근사치): 500 kg/km
TX® ( I ) 331 150/250V 10P1.5
Nexans ref. 10253714
- Packaging: Cut to length (m)
- Number of pairs: 10
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 21.0 mm
- Maximum outer diameter: 24.0 mm
- 무게(근사치): 700 kg/km
TX® ( I ) 331 150/250V 14P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 14
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 24.0 mm
- Maximum outer diameter: 27.0 mm
- 무게(근사치): 950 kg/km
TX® ( I ) 331 150/250V 19P1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: 19
- Number of triples: -
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 28.0 mm
- Maximum outer diameter: 31.0 mm
- 무게(근사치): 1260 kg/km
TX® ( I ) 331 150/250V 1T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 1
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 8.2 mm
- Maximum outer diameter: 9.6 mm
- 무게(근사치): 110 kg/km
TX® ( I ) 331 150/250V 2T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 2
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 14.5 mm
- Maximum outer diameter: 16.5 mm
- 무게(근사치): 300 kg/km
TX® ( I ) 331 150/250V 4T1.5
Nexans ref.
- Packaging: Cut to length (m)
- Number of pairs: -
- Number of triples: 4
- 도체 단면적: 1.5 mm²
- Minimum outer diameter: 16.0 mm
- Maximum outer diameter: 18.5 mm
- 무게(근사치): 410 kg/km
Description
Description
Standards
-
ProductIEC 60228
-
InstallationIEC 60092-350; IEC 60092-351; IEC 60092-360; IEC 60092-376
-
TestIEC 60331-1 or 2; IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034
Application
TX® (I) 331 150/250 V fire resistant overall and individually screened twisted pair cables maintain circuit integrity in case of fire by meeting performances requirements from the IEC 60331 series for 90 minutes. These telecommunication and instrumentation cables show a strong protection aganist cross-talk and result into a good compromise between TX® (C) 331 and TCX® (C) 331 cables against external electromegnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.
Design
1. Conductor:
Stranded bare copper
Class 2
2. Insulation: Mica tape + XLPE (cross-linked polyethylene)
Optional: Special fire resistant HF 90 (halogen-free compound)
with INFITTM technology
3. Individual screen:
Alu/polyester tape with a tinned copper drain wire
4. Outer sheath:
Polyolefin SHF1 (SHF2 on request)
Colour: orange
Marking
I NEXANS I TX (I) 331 150/250 V "n x 2 or 3 x s" mm² 90 °C - IEC 60092-376 IEC 60332-3-22 Cat. A IEC 60331-1/2 ww/yy - CE + metric marking
Core identification
- Core 1 : white
- Core 2 : blue
- Core 3 : red
- Double identification: conductor and pair
Characteristics
Characteristics
구조적 특성
구조적 특성
전기적 특성
전기적 특성
사용 특성
사용 특성
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania